
LITHIUM SOLAR PWM INVERTER 2100VA 25.6V
Key Feature
• Lithium Solar Inverter - Integrates battery-backed AC power conversion with photovoltaic charging for a 25.6V lithium system.
• 2100 VA Capacity Class - Provides the stated inverter VA class for correctly planned solar and backup loads.
• PWM Charging Architecture - Uses the stated solar-charging format within the inverter platform.
• 25.6V Battery Platform - Designed around the specified lithium battery-voltage class and corresponding DC power path.
• Solar Backup Integration - Suited to home, office, CCTV, networking and off-grid applications using matched PV and battery systems.
₹10,850.00
Lithium Solar PWM Inverter 2100 VA 25.6V
The Lithium Solar PWM Inverter 2100 VA 25.6V is a 2100 VA lithium solar inverter for a 25.6V battery system. It combines battery-backed AC inversion with solar charging in one platform, using a built-in PWM solar charge-control method.
The solar inverter sits between the photovoltaic array, lithium battery, utility supply where used and the connected AC loads. The 2100 VA capacity describes the inverter output class, while 25.6V defines the battery-side voltage. Solar charging and AC conversion share the same energy system, so PV array sizing, battery charging limits and load demand need to be engineered as one installation.
PWM solar charging uses switched connection between the panel array and battery-charging stage rather than maximum-power-point tracking. The reviewed 2100VA 25.6V PWM product is documented for LiFePO4 battery systems and pure sine wave AC output. It provides an integrated solar-charging route for installations designed around the corresponding panel and battery voltage requirements.
Solar-controller type changes how the PV array is selected but does not change the basic battery-energy calculation. Battery watt-hours determine stored energy, inverter efficiency affects usable AC energy, and the load determines runtime. Solar input can extend operating time when generation is available, but a panel array does not give the inverter permission to exceed its AC output capability.
Lithium battery charging requires settings suited to the battery system and its BMS. PV open-circuit voltage must stay inside the inverter solar-input limit, DC cables need to carry the charging current safely, and AC loads should be separated according to their importance and surge demand. Refrigerators, pumps and other motor loads can require substantially more power at start-up than during steady operation.
Applications
• Home backup systems supplying lighting, fans, networking and selected household loads.
• Solar energy-storage installations combining photovoltaic input, battery storage and AC loads.
• Small-office and commercial backup systems requiring automatic transition between available energy sources.
• Off-grid and weak-grid sites where battery storage supports continuous AC power availability.
• CCTV, telecom, networking and control equipment requiring stable inverter-backed power.
• Custom ESS and inverter-battery projects built around the stated power and battery-voltage class.
Installation Guide
Have a competent installer isolate all AC, battery and PV sources before wiring or accessory installation. Mount the equipment with the ventilation clearances required by the system, route battery and solar conductors away from sharp edges, and use cables, terminals and protective devices sized for the actual current. Establish polarity and source separation before energising any DC connection.
Commission the system progressively. Establish battery voltage and polarity, apply the required inverter settings, energise one source at a time and observe the display or monitoring data before connecting the full load. Test normal source transfer and charging behaviour with a controlled load rather than beginning at maximum demand. Stop commissioning if wiring heats, protection trips repeatedly or the system reports unstable electrical values.
Record the inverter model, battery settings, source priorities, cable sizes and commissioning measurements with the installation. Keep ventilation paths clean and inspect high-current terminals during service for heat marks or looseness. Changes to battery type, PV array, connected loads or parallel architecture require renewed engineering review because earlier settings may no longer suit the revised system.
Why Choose ARB Accessories?
ARB Accessories supplies hybrid inverters and monitoring accessories alongside lithium battery packs, BMS products, solar components, ESS connectors, high-current cable, fuses and battery hardware for Indian system builders. Prepare your enquiry with the 2100 VA power class, 25.6V battery system, solar-controller type, PV array voltage and connected-load profile so the inverter or accessory can be matched to the complete electrical architecture rather than selected from power rating alone. System performance also depends on conductor sizing, protective devices, ventilation and battery capability, because an inverter can only deliver its intended output when the surrounding electrical path is designed for the same power level. For repeatable installations, recording battery settings, source priorities and commissioning measurements makes future service work faster and reduces configuration differences between otherwise similar systems.
Product overview
Lithium Solar PWM Inverter 2100 VA 25.6V The Lithium Solar PWM Inverter 2100 VA 25.6V is a 2100 VA lithium solar inverter for a 25.6V battery system.
- SKU
- 26001373
- Category
- HYBRID INVERTER
- Unit
- PCS
- Minimum order
- 1 PCS
- Availability
- In Stock
Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.