LEAD ACID BATTERY TESTING MACHINE CD6G-312
Key Feature
• Six Test Channels - Evaluate six batteries in one station.
• 12V / 16V Batteries - Dedicated lead-acid operating scope.
• 3A Adaptive Charging - A separate rating from discharge current.
• 1-12A Discharge - Set the load for the battery test.
• Automatic Sequences - Combine charging and capacity evaluation.
₹24,990.00
Languang CD6G-312 Six-Channel Lead-Acid Battery Tester
The Languang CD6G-312 is a six-channel lead-acid battery testing machine for controlled charging and discharge-capacity evaluation. The documented configuration serves 12V and 16V batteries and allows several identified batteries to be assessed at one station.
This is useful for service teams comparing individual batteries from an electric-vehicle or storage application. A structured charge and discharge procedure provides more information than a quick voltage check. Keep each battery associated with its channel and test record so the results support a clear service decision.
The manufacturer manual specifies 3A adaptive charging and an adjustable discharge current from 1A to 12A. These are different operating ratings: the discharge range must not be presented as the charger's output range. Automatic sequences combine charging and discharging, while separate modes support charging or discharge-capacity testing alone.
The result must be interpreted against the battery's own rated test conditions. A capacity claim based on one discharge rate is not directly comparable with an arbitrary workshop load. Battery condition, temperature and preparation also affect the outcome. Service or repair functions should not be described as a guarantee of restored capacity; physically damaged or internally defective batteries may require replacement rather than further treatment.
Confirm the supplied CD6G-312 revision and battery-voltage selection against its manual. This instrument's documented scope is lead-acid service, not an unrestricted lithium charging profile. Check the permissible current and charging method for the battery type before choosing a work sequence.
For multi-battery jobs, define a consistent channel-labelling system and avoid mixing test conditions within a comparison group. Similar external dimensions do not establish identical capacity ratings or chemistry. Check terminal condition, ventilation and the battery manufacturer's service requirements. Where batteries are normally installed in a series assembly, use only the connection arrangement explicitly approved for individual-channel testing.
Applications
• Capacity comparison of compatible lead-acid batteries.
• Service evaluation of 12V and 16V battery units.
• Multi-battery workshop charging and discharge checks.
• Investigation of reduced runtime in matched battery sets.
• Maintaining individual battery test and service records.
Installation Guide
Install the machine on a firm, ventilated bench with the specified grounded supply. Keep its cooling openings clear and ensure the battery area is adequately ventilated for lead-acid charging. Inspect insulation and verify polarity for each channel before enabling a sequence.
Commission with an approved reference battery and confirm the selected voltage mode, discharge current and stop behaviour. Label every channel and retain results before moving batteries. Stop for leakage, swelling, abnormal heating or unexpected operation. Advanced service modes require a manufacturer-approved procedure and competent supervision; they should not be used casually to force a failed battery back into service. Follow appropriate battery handling and recycling procedures for rejected units.
Why Choose ARB Accessories?
ARB Accessories supplies battery-testing equipment for Indian service centres and assembly businesses. Provide the battery voltage, capacity rating and number of units to be tested when discussing the CD6G-312. A clearly specified six-channel workflow helps align the instrument, workbench and recordkeeping, while separating normal capacity testing from specialised maintenance that requires additional assessment.
Product overview
Languang CD6G-312 Six-Channel Lead-Acid Battery Tester The Languang CD6G-312 is a six-channel lead-acid battery testing machine for controlled charging and discharge-capacity evaluation.
- SKU
- 26000673
- Category
- BATTERY TESTERS
- Unit
- PCS
- Minimum order
- 1 PCS
- Availability
- In Stock
Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.