IEC SCREW MOUNT MALE CONNECTOR WITH RUBBER COVER
Get notified when this product is back in stock.
Key Feature
• Screw-Mount Male Connector - Designed for fixed installation on a compatible enclosure or panel.
• Rubber Protective Cover - Helps shield the connector opening when not in use.
• Serviceable Power Inlet - Creates a removable connection point for equipment wiring.
• Enclosure Integration - Useful on chargers, inverters, testers and electrical cabinets.
• IEC-Style Connection - Match the exact mating connector and electrical rating before use.
₹11.00
Get notified when this product is back in stock.
IEC SCREW MOUNT MALE CONNECTER WITH RUBBER COVER
The IEC SCREW MOUNT MALE CONNECTER WITH RUBBER COVER is a panel-mount male IEC-style power connector with a protective rubber cover used to create a removable electrical connection in battery, charger, inverter, EV or equipment wiring where the mating interface matches. Common buyer searches include IEC screw mount male connector, IEC panel mount inlet, male power inlet with rubber cover, panel mount power connector, and the product is most useful when installers want a serviceable connection rather than repeatedly disturbing fixed battery terminals. The screw-mount body is intended to be fixed to a panel or enclosure so the connection remains mechanically supported during repeated use.
A connector assembly should be treated as part of the complete current path. Contact resistance, conductor size, termination quality, mating condition and ambient temperature all influence how much current a finished connection can carry without excessive heating. The housing name alone is not a substitute for checking the actual contact and cable combination.
Good DC connector performance depends on low-resistance metal-to-metal contact and secure mechanical retention. Poor crimping, loose contacts, contamination or partial engagement can increase resistance, which becomes important in battery circuits because heat rises rapidly with current. The rubber cover can shield the opening from handling contamination when not in use, but it should not be described as providing a specific waterproof or IP rating unless the complete product is certified for that rating. For pre-wired connector leads, cable length also affects voltage drop, while panel-mount connectors require a secure enclosure cut-out and enough rear clearance for the conductors.
Polarity marking and housing orientation should be treated as installation controls rather than assumptions. Matching halves need compatible geometry and contact size, and any protective cap or cover should be used only in the way intended by the connector design. Do not assign an enclosure IP rating unless the complete mated assembly has a verified rating.
Before ordering, match the mating connector family, number of poles, contact size, cable gauge, system voltage and expected operating current. For replacement work, compare the physical housing and terminal shape with the existing connector, because similar-looking DC power connectors are not always interchangeable. If the connector is part of a battery-to-controller or charger cable, size the complete harness for current, voltage drop, fuse coordination and mechanical routing. Also check bend radius and strain relief so cable movement cannot pull directly on the contacts.
Applications
• Battery charger and inverter enclosures.
• Power distribution panels and workshop equipment.
• Battery testing and assembly-machine cabinets.
• Portable power and control boxes.
• Serviceable AC/DC equipment inlet points where the exact connector type matches.
Installation Guide
Isolate the battery or power source before fitting or replacing the connector. Confirm positive and negative polarity with a meter and mark the conductors before disconnecting an existing harness. Use the correct crimping or termination method for the supplied contacts, then perform a firm pull check before energizing the circuit. Keep conductive tools away from live battery terminals, route the cable so it cannot chafe against sharp edges, and provide strain relief near the connector. After assembly, verify full mating engagement and check the connection for abnormal heating during an initial controlled load test.
Why Choose ARB Accessories?
ARB Accessories focuses on lithium-battery, EV, energy-storage and battery-pack assembly components. The catalog brings together BMS boards, connectors, insulation materials, battery wiring, terminals, fuses, enclosures, testing equipment and assembly tools. For battery builders, repair workshops and OEM buyers, sourcing related components from one specialist catalog can make specification matching and procurement easier. Final suitability should still be checked against the exact battery design, equipment model and electrical requirements before installation.
Product overview
IEC SCREW MOUNT MALE CONNECTER WITH RUBBER COVER The IEC SCREW MOUNT MALE CONNECTER WITH RUBBER COVER is a panel-mount male IEC-style power connector with a protective rubber cover used to create a removable electrical connection in battery, charger, inverter, EV or equipment wiring where the mating interface matches.
- SKU
- 26001169
- Category
- POWER CONNECTOR (IEC+XT)
- Unit
- PCS
- Minimum order
- 50 PCSs
- Availability
- Out of Stock
Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.
Datasheet
Datasheet