1. Home
  2. BATTERY TESTERS
GLITTER BATTERY PACK TESTER G886A
Glitter

GLITTER BATTERY PACK TESTER G886A

SKU: 26000630|MOQ: 1 PCS
Base Price:
₹8,431.00
GST 18%:₹1,517.58
Final Price (Inclusive of all taxes):₹9,948.58 / PCS

Key Feature

• Cell-Level Evaluation - Screen cells used in battery assembly.

• Low-Voltage Scope - Documented G886A testing is within 5.5V.

• Selectable Cell Load - Choose 0.5A, 1A or 2A.

• Capacity and Resistance - Review two useful cell measurements.

• Bench Test Workflow - Keep results linked to each sample.

MOQ: 1 PCS

₹8,431.00

Item Code26000630
Product NameGLITTER BATTERY PACK TESTER G886A
CategoryBATTERY TESTERS
Unit of MeasurePCS
ModelG886A

GLITTER G886A Battery Workshop Cell Capacity Tester


The GLITTER G886A supports cell-level capacity and resistance checks in battery assembly and maintenance workshops. Its documented low-voltage configuration is for individual rechargeable cells; it must not be treated as a high-voltage pack tester.


Within a pack-building workflow, this distinction matters. Cells can be screened before assembly, while a completed battery requires equipment matched to its full series voltage and output current. The G886A can therefore form part of a workshop's cell evaluation process without replacing the separate tests needed to assess an assembled battery.


The documented G886A cell-testing range extends to 5.5V, with 0.5A, 1A and 2A test-current selections. Capacity and resistance results help describe how a cell behaves under the selected conditions. The current setting is a test parameter, not a recommendation that every cell should be charged or discharged at that rate.


Compare like with like: use the same approved charge preparation, rest period and discharge endpoint for samples being considered for one group. A cell with a normal resting voltage can still give an unsatisfactory capacity result. Conversely, a poor test contact can distort the measurement and should be investigated before rejecting a cell. Treat the result as evidence for a defined decision, not as a complete battery health certificate.


Start by identifying the physical item and its voltage label. Equipment names containing battery pack do not establish an electrical rating. When the intended job involves a finished multi-cell battery, select a tester specifically rated for that pack rather than connecting it to this documented single-cell configuration.

For cell testing, verify the holder, contact spacing, chemistry-specific limits and the instrument's supported charging mode. Do not assume that changing a current setting also changes the lithium charge-voltage profile. Keep the appropriate protective circuit in the test arrangement and use qualified personnel for any work involving access to cells inside an assembled pack.


Applications

• Cell screening before battery pack construction.

• Workshop comparison of identified rechargeable samples.

• Incoming cell checks for replacement-part selection.

• Bench training in capacity measurement principles.

• Supporting records for a broader battery diagnostic process.


Installation Guide

Set up an insulated testing area with clear airflow around the instrument. Inspect the leads and fixtures, verify the mains supply version and establish polarity before connection. Keep sample labels visible so results cannot become separated from the cells being evaluated.


Begin with a known reference sample and confirm that the chosen test mode behaves as expected. Review the completed result before testing customer samples. After testing, return cells to the storage condition required by their manufacturer. Do not attempt to make a weak or damaged cell suitable for reuse simply by repeating charge cycles; investigate the fault and follow the workshop's rejection procedure.


Why Choose ARB Accessories?

ARB Accessories brings together battery-testing instruments and components for Indian pack assemblers and service teams. Share a photograph of the G886A label and explain whether your work concerns loose cells or complete batteries. Resolving that distinction at enquiry stage helps match the tester, wiring and fixtures to the task, while keeping the purchasing record clear for future replacements and operator training.

Product overview

GLITTER G886A Battery Workshop Cell Capacity Tester The GLITTER G886A supports cell-level capacity and resistance checks in battery assembly and maintenance workshops.

SKU
26000630
Category
BATTERY TESTERS
Brand
Glitter
Unit
PCS
Minimum order
1 PCS
Availability
In Stock

Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.

Datasheet

Datasheet

File unavailable

Similar Items

© 2026 ARB Accessories. All rights reserved.