Key Feature
• 9-99V Pack Scope - Match the complete battery voltage range.
• Up to 50A Both Ways - Controlled charging and discharging.
• Automatic Cycling - Apply repeatable battery evaluation steps.
• Temperature Monitoring - Use approved sensors and alarm settings.
• LAN Test Reporting - Review curves and export Excel records.
₹1,17,750.00
DK BPT50 99V 50A Battery Pack Capacity Tester
The DK BPT50 is an industrial battery pack capacity tester with controlled charging and discharging up to 50A. Its 9-99V battery range and documented three-phase supply requirement make electrical-service planning an important part of equipment selection.
For production or engineering teams, a suitable pack tester provides both an operating procedure and a record of what occurred. Define the purpose of the test before choosing its current and duration. Capacity verification, repeated cycling and investigation of an early protective cutoff may require different procedures and different acceptance criteria.
The BPT50 supports constant-current/constant-voltage charging, constant-current discharge, automatic cycling and DC internal-resistance evaluation. Battery-temperature monitoring and configurable responses are included in the documented platform. Panel operation and LAN-connected software provide local control or computer-based records, including Excel reports.
The 50A figure is a maximum current capability, not a universal recommendation for connected batteries. Check the full operating envelope and the ratings of the cells, BMS, connectors and test harness. A temperature alarm depends on correct sensor placement and configuration; it is not a substitute for an appropriate test environment. Interpret a protective stop separately from normal completion and preserve the evidence needed for subsequent investigation.
Verify that the battery's maximum charged voltage and minimum permitted endpoint fit within the tester's range. Confirm the continuous-current requirement in both directions and any BMS restrictions. A battery that can discharge at 50A may not permit charging at the same rate.
Have a qualified electrician check the documented three-phase supply requirement before allocating floor space or ordering a plug arrangement. Do not assume compatibility with a domestic single-phase socket. Specify fixtures, temperature sensing, computer access and report storage together. For repeated production work, protect approved test recipes from unintended changes and keep each result linked to the correct pack and hardware revision.
Applications
• Industrial capacity verification of compatible battery packs.
• Controlled high-current charge-discharge evaluation.
• Repeated pack ageing and performance comparison.
• DC resistance and temperature-aware diagnostic testing.
• Production and service reporting with traceable pack records.
Installation Guide
Install the equipment with the correct three-phase service, protective earthing, ventilation and working clearances. Secure the battery and have qualified personnel commission current, sensing and temperature connections. Verify polarity and the approved recipe before enabling a load.
Start with a reference pack and a conservative current, then validate the intended operating conditions. Check sensor readings, connector temperature and software identification throughout the initial run. Confirm that the completed report contains the procedure and stop condition as well as capacity. Stop for abnormal battery behaviour or connection problems. Maintain calibration and harness inspection records, and retain interrupted tests alongside any later retest rather than treating them as disposable data.
Why Choose ARB Accessories?
ARB Accessories offers battery-testing equipment and related battery components for Indian manufacturers and service facilities. Include your pack voltage, permitted charge/discharge currents and available electrical supply when discussing the BPT50. This supports a coordinated equipment enquiry and helps establish whether the site, fixtures and reporting process are ready for the intended industrial battery-testing work.
Product overview
DK BPT50 99V 50A Battery Pack Capacity Tester The DK BPT50 is an industrial battery pack capacity tester with controlled charging and discharging up to 50A.