1. Home
  2. AUTOMATIC MACHINES
CELL TESTING MACHINE (EST-BF5V30A-128CH)
EST

CELL TESTING MACHINE (EST-BF5V30A-128CH)

SKU: 26000706|MOQ: 1 PCS
Base Price:
₹9,27,024.00
GST 18%:₹1,66,864.32
Final Price (Inclusive of all taxes):₹10,93,888.32 / PCS
Out of Stock

Get notified when this product is back in stock.

Key Feature

• 128 Test Channels - Keep individual cell measurements organised.

• 5V / 30A Class - Apply the approved voltage and test-current limits.

• Energy-Feedback Design - Use regenerative discharge during testing.

• Programmable Cycling - Repeat defined charge and discharge procedures.

• Excel Test Reports - Export records for quality review and comparison.

MOQ: 1 PCS

₹9,27,024.00

Out of Stock

Get notified when this product is back in stock.

Item Code26000706
Product NameCELL TESTING MACHINE (EST-BF5V30A-128CH)
CategoryAUTOMATIC MACHINES
Unit of MeasurePCS
ModelEST-BF5V30A-128CH

EST BF5V30A-128CH Regenerative Battery Cell Capacity Tester


The EST BF5V30A-128CH is a regenerative battery cell capacity tester with 128 channels in the 5V, 30A class. It provides a platform for controlled electrical cycling of compatible cells where both batch capacity and a higher test-current class are required.


The model identifies 30A current, not 30V output. This distinction matters when specifying a cell-testing station: the equipment is intended for suitable individual cells within its operating range, not for treating each channel as a general high-voltage battery pack tester.


The system combines programmable charge-discharge testing with individual channel measurement and an energy-feedback architecture. Test records can be reviewed and exported in Excel format, supporting comparison of results obtained under the same approved conditions. Preserve the selected procedure alongside the data so that a capacity value can be interpreted correctly.


The 30A rating is not a universal test setting or an ampere-hour capacity limit. Choose current from the cell's permitted charge and discharge conditions, and confirm the mode-specific voltage limits of the supplied equipment. Capacity results also depend on temperature, termination conditions and the complete test method.


The channel count represents electrical test positions. It does not describe mechanical sorting outlets or imply that channels can be connected in series or parallel without a specifically approved configuration. Keep those distinctions clear when planning the station and comparing it with other production equipment.


Provide the cell drawing, terminal arrangement, capacity, approved test current and required discharge endpoint when enquiring about this tester. Confirm the supplied fixtures and contact method against those requirements. A cell that meets the electrical limits still needs a suitable mechanical connection and stable contact throughout the cycle.


Define the required identification fields, reports and acceptance criteria before commissioning. Clarify the current hardware revision, software functions and supplied accessories in the purchase specification. For a high-channel-count installation, also plan safe loading, sample separation, cable routing and operator access. Estimate production capacity from the entire cycle and handling sequence rather than converting 128 channels directly into an hourly throughput claim.


Applications

• Capacity evaluation of suitable individual battery cells.

• Higher-current cell cycling under an approved procedure.

• Batch comparison for battery manufacturing quality control.

• Collection of cell test records for grading decisions.

• Development testing of compatible cell and fixture combinations.


Installation Guide

Installation should be completed by qualified personnel using the electrical services, protective earth, feedback connection and ventilation specified for the delivered unit. Check each fixture and contact before connecting production cells. Maintain the clearances and sample-handling arrangements required by the cell and equipment manufacturers.


Commission an approved sample group and verify polarity, channel identity, operating limits and the completed reports. Keep the authorised test recipe with the batch records and review unexpected results before proceeding. Inspect contacts and current-carrying components regularly, maintain calibration records and stop testing cells that show abnormal behaviour. Regenerative operation does not remove the need for these basic controls.


Why Choose ARB Accessories?

ARB Accessories brings together battery cells, testing equipment, BMS boards, connectors and assembly consumables for Indian battery businesses. Discuss the cell specification, test current and fixture requirement together when selecting this machine. Coordinating these requirements through a specialist battery-production catalog helps procurement teams prepare a clearer enquiry and avoid ordering equipment solely by its headline channel count.

Product overview

EST BF5V30A-128CH Regenerative Battery Cell Capacity Tester The EST BF5V30A-128CH is a regenerative battery cell capacity tester with 128 channels in the 5V, 30A class.

SKU
26000706
Category
AUTOMATIC MACHINES
Brand
EST
Unit
PCS
Minimum order
1 PCS
Availability
Out of Stock

Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.

Datasheet