Key Feature

• 512 Independent Channels - High-throughput simultaneous cell testing.

• 5V / 3A Per Channel - Designed around cylindrical lithium-cell charge/discharge work.

• Capacity Grading - Supports production sorting and pack-matching workflows.

• Cylindrical Cell Compatibility - Listings reference common 18650, 21700 and 26650 formats.

• Production-Scale Cabinet - Intended for battery manufacturing and quality-control lines.

MOQ: 1 PCS

₹4,15,000.00

Out of Stock

Get notified when this product is back in stock.

Item Code26000689
Product Name512 CH BATTERY CELL CABINET 5V 3A SKXD-512-5V 3A
CategoryAUTOMATIC MACHINES
Unit of MeasurePCS
ModelSKXD-512-5V3A

SunkaLead SKXD-512-5V 3A 512-Channel Cylindrical Cell Capacity Cabinet


The SunkaLead SKXD-512-5V 3A is a 512-channel cylindrical battery cell cabinet for charging, discharging and capacity grading. It combines a 5V measurement class with charge and discharge current up to 3A per channel for organised batch evaluation.


This configuration is relevant when a battery assembler needs individual results for many cells processed through a common production procedure. It is a capacity-testing station rather than a mechanical bin sorter. The output should therefore feed an organised collection and labelling process so that measured grades remain associated with the correct cells.


The cabinet uses separate current and voltage-source circuits for its test positions. Its workflow includes constant-current/constant-voltage charging and constant-current discharge, with computer-based curves and cell-level information available for review. Fixture indicators assist the operator in identifying capacity grades after a completed discharge.


Separate measurement circuits should not be confused with permission to assign a different recipe to every position. Plan production batches around the configured workflow. The 5V measurement class also must not be interpreted as a recommendation to charge lithium cells to 5V. Test cutoffs belong to the approved cell specification and the operating range of the selected mode.


For meaningful capacity comparisons, keep current, end voltage, rest conditions and temperature consistent. Retain incomplete or abnormal records rather than mixing them with successfully finished tests.


Match the cell diameter, length and terminal shape to the supplied quick-clamping fixtures. For mixed-format production, establish a documented changeover procedure instead of assuming that every cylindrical size fits without adjustment.


Calculate the required channel capacity from the complete test duration, loading time and review process. More test positions do not shorten the charging time required by a cell. Also specify how staff will identify failed tests, collect each grade and transfer results to the batch record. This prevents a large cabinet from producing a large volume of measurements without a reliable route to usable production decisions.


Applications

• Batch capacity grading of compatible cylindrical cells.

• Incoming quality inspection for lithium battery assemblers.

• Comparing supplier lots under the same test method.

• Production sampling before cylindrical module assembly.

• Recording charge and discharge curves for quality review.


Installation Guide

Provide the electrical service, protective earth, ventilation and maintenance clearance required by the delivered cabinet. Commission the machine with trained electrical and production personnel. Inspect cell insulation and clean contact surfaces before loading; poor contact should be treated as a test problem rather than immediately classifying the cell as defective.


Validate a small reference batch, review channel readings and check the grade indicators before filling the cabinet. Keep the approved recipe under revision control, preserve exported records and schedule calibration and fixture maintenance. When a test is interrupted, apply the documented restart or retest procedure rather than assuming its capacity result is comparable with an uninterrupted cycle.


Why Choose ARB Accessories?

ARB Accessories brings together battery cells, testing equipment, BMS boards, connectors and assembly consumables for Indian battery businesses. Discuss the cell specification, test current and fixture requirement together when selecting this machine. Coordinating these requirements through a specialist battery-production catalog helps procurement teams prepare a clearer enquiry and avoid ordering equipment solely by its headline channel count.

Product overview

SunkaLead SKXD-512-5V 3A 512-Channel Cylindrical Cell Capacity Cabinet The SunkaLead SKXD-512-5V 3A is a 512-channel cylindrical battery cell cabinet for charging, discharging and capacity grading.

SKU
26000689
Category
AUTOMATIC MACHINES
Brand
SunkaLead
Unit
PCS
Minimum order
1 PCS
Availability
Out of Stock

Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.

Datasheet

Datasheet

OpenDownload

Similar Items

© 2026 ARB Accessories. All rights reserved.