Key Feature

• 512 Test Channels - Organise large batches of individual cells.

• Capacity Evaluation - Compare results from controlled discharge tests.

• Programmable Test Steps - Structure repeatable charge-discharge routines.

• PC Monitoring - Review cell voltage, current and test progress.

• Exportable Records - Keep batch results for production analysis.

MOQ: 1 PCS

₹7,48,500.00

Out of Stock

Get notified when this product is back in stock.

Item Code26000690
Product Name512 CH BATTERY CELL CABINET 5V 6A SKXD-512-5V6A
CategoryAUTOMATIC MACHINES
Unit of MeasurePCS
ModelSKXD-512-5V6A

SunkaLead SKXD-512-5V 6A 512-Channel Battery Cell Capacity Cabinet


The SunkaLead SKXD-512-5V6A is a 512-channel battery cell capacity cabinet for production-scale charge and discharge evaluation. It brings individual-cell testing, computer monitoring and batch records into a single cabinet workflow for cylindrical-cell processing.


The main purchasing question is not simply how many cells can be loaded. A useful installation must connect each result to a physical position, preserve the test procedure and support orderly collection after completion. For a battery-pack manufacturer, those operational details determine whether a large test batch can become a dependable set of cell groups for assembly.


The machine supports programmed testing and computer-based review of voltage, current and test progress. Capacity evaluation uses a controlled discharge procedure rather than a brief voltage check. Exportable records allow the production team to compare completed batches and investigate unusual results separately from the normal flow.


A model designation identifies a configuration; it should not become the test recipe. The selected charging current, discharge current and voltage cutoffs must suit the cell specification and the delivered equipment's operating limits. Higher test current is useful only when the cell and the required comparison method permit it.


When comparing batches, maintain the same test conditions and distinguish failed connections, interrupted tests and genuinely low-capacity cells. Combining these outcomes into one reject category can hide avoidable fixture or process problems.


Assess cell dimensions, terminal access, fixture contact quality and the intended batch size together. Define the number of grades actually required by the pack design, then decide how finished cells will be collected and labelled. Capacity grading should remain traceable when cells leave the cabinet and move to a separate sorting or assembly station.


For production planning, use the complete cycle duration rather than an assumed cells-per-hour figure. Include loading, resting, review, retesting and unloading. Clarify the computer arrangement, record retention and operator responsibilities before commissioning. A documented workflow is especially valuable when several staff members share responsibility for a large batch across different shifts.


Applications

• Large-batch cylindrical-cell capacity evaluation.

• Charge-discharge testing before battery pack assembly.

• Incoming lot comparison using approved procedures.

• Production quality records for individual test positions.

• Investigation of cell-to-cell variation within a batch.


Installation Guide

Install the cabinet with the specified supply, protective earth, cooling clearance and access for service. The electrical installation must be designed for the actual delivered configuration, not inferred from a similar cabinet. Have trained personnel check fixture wiring and communications before loading production cells.


Begin with a small, identified reference batch. Confirm that recorded channels match physical positions and that abnormal or interrupted results remain distinguishable. Keep approved settings under revision control and retain the original data alongside exported reports. Maintain clean contacts and calibration records, and reassess the procedure whenever cell type, fixture arrangement or test requirements change.


Why Choose ARB Accessories?

ARB Accessories brings together battery cells, testing equipment, BMS boards, connectors and assembly consumables for Indian battery businesses. Discuss the cell specification, test current and fixture requirement together when selecting this machine. Coordinating these requirements through a specialist battery-production catalog helps procurement teams prepare a clearer enquiry and avoid ordering equipment solely by its headline channel count.

Product overview

SunkaLead SKXD-512-5V 6A 512-Channel Battery Cell Capacity Cabinet The SunkaLead SKXD-512-5V6A is a 512-channel battery cell capacity cabinet for production-scale charge and discharge evaluation.

SKU
26000690
Category
AUTOMATIC MACHINES
Brand
SunkaLead
Unit
PCS
Minimum order
1 PCS
Availability
Out of Stock

Review key features and technical specifications before ordering. Contact ARB Accessories if you need compatibility or bulk-order guidance.

Datasheet

Datasheet

File unavailable

Similar Items

© 2026 ARB Accessories. All rights reserved.